Typical 5 Wire 2 Step Unlock/Lock Wiring Diagram
2 Pin Door Lock & 2nd Unlock Harness: (White Connector)
The Red & Green Door Lock & 2nd Unlock output wires provide either a pulsed ground or pulsed + 12 volts to control
the vehicle door locks & 2nd unlock circuits. The output of these wires have a maximum switching capability of
300mA. Many vehicles today have factory door lock relays which can be connected directly to these outputs,
however always confirm that the factory relays in your particular vehicle do not exceed the rated 300mA output of the
unit's door lock & 2nd unlock outputs. Plug the two pin connector of the door lock / 2nd unlock harness into the
mating 2 pin connector shell of the control module. Determine the door lock circuit of the vehicle you are working
with and wire accordingly.
NOTE: The 2nd unlock output will not be used if you are installing the system in the vehicle using a "One Step"
unlocking system. This output, in this configuration, may be used as a additional channel output but must be wired
accordingly. To access this output see the transmitter programming section shown later in this manual.
3 Wire Ground Switched Door Lock Circuits:
In this application, the Red wire of the two pin harness provides a ground pulse during the arming sequence, or
pulsed ground lock output. Connect the Red wire to the low current ground signal from the factory door lock switch
to the factory door lock relay.
The Green wire of the two pin harness provides a ground pulse during the 2nd step disarming sequence, or pulsed
ground 2nd unlock output. Connect the Green wire to the low current ground signal from the factory door unlock
switch to the factory door unlock relay.
3 Wire Positive Switched Door Locks:
In this application, the Red wire of the two pin harness provides a + 12 volt pulse during the 2nd step disarming
sequence, or pulsed 12 volt 2nd unlock output. Connect the Red wire to the low current 12 volt signal from the
factory door unlock switch to the factory door unlock relay.
The Green wire of the two pin harness provides a + 12 volt pulse during the arming sequence, or pulsed 12 volts
lock output. Connect the Green wire to the low current 12 volt signal from the factory door lock switch to the factory
door lock relay.
Note: For connection to Four Wire Polarity Reversal, 5 Wire Alternating 12 Volts, And All Other Door Lock Circuits
the Audiovox AS-9159 Door Lock Interface, or equivalent 30 A automotive Relay must be used. Refer to the
Audiovox Door Lock Wiring Supplement for proper wiring of these circuits.