A SERVICE OF

logo

XLB-4725A
5-2
B06-00-0334
THIS PLUG 115 VOLT
RIL
B06-00-0062
B06-00-0062
B06-00-0130
LUBRICATE
MONTHLY
B06-00-0130
RIF
B06-00-0268OFA
B06-00-0268
EMERGENCY ROTATION HANDLE
COFC B06-00-0192
B06-00-0192
OPERATION AND SERVICE
MANUAL INSIDE
DANGER
FAILURE TO COMLY WITH THE FOLLOWING SAFETY INSTRUCTIONS OR ANY OTHER USE
OFTHIS EQUIPMENTWILL RESULT IN SERIOUS INJURY OR DEATH.
BEFORE USE
•Operatormust read and understandowners manual and all decals on machine before operating.It is
operators responsibility to comply with all warnings and instructions.
• Survey the job site and identify all potential hazards.
• Inspect lift for proper maintenance and any damaged or worn components.DO NOT operate until proper
maintenance has been performed and all damaged or worn parts have been replaced. See owners manual for
proper maintenance procedures.
• NEVER TAKE CHANCES—DO NOT use this lift if you are under the influence of drugs or alcohol, or if you feel
dizzy,ill, or unsteady in any way.
• OPERATE ON FIRM AND LEVEL SURFACE ONLY—if used on loose gravel or other soft surfaces, the large
square support pads should be added to the base of the outriggers.Additional base support may be
necessary on excessively soft footing.
• Extend, lock, and stabilize all four outriggers.
• Level machine before use—if buzzer sounds, lift is not level and the necessary outrigger adjustment should
be made to level machine before continuing.
• All occupants must wear full body harness and lanyard.
• Check safety devices daily before use—see owners manual for proper check procedures.
• When working on public roads, warnings and barriers must be set up in accordance with all local, state, and
federal traffic codes.
• Cordon off area around base to keep personnel and other equipment away from unit while in use.
DURING USE
• To avoid hand injuries, always keep hands inside basket area during boom movement.
• DO NOT use without all four outriggers fully extended, locked and stabilized.
• DO NOT release outriggers with boom extended or operator in basket.
• DO NOT move or reposition trailer while operator occupies basket.
• DO NOT use when exposed to high winds, rain, snow, or ice.
• DO NOT use where lift operator can come in contact with overhead obstructions such as electric wires, cables,
ropes, overhangs, etc.
• DO NOT operate without full body harness and lanyard in use by all basket occupants.
• DO NOT stand or sit on guard rails or top edge of basket.
• DO NOT lean out over top edge of basket to perform work.
• DO NOT use boxes, ladders,scaffolding, or any other
means to increase working height.
• DO NOT climb up or down boom.
• DO NOT exceed rated lift capacity.
• DO NOT allow ropes, electric cords, hoses,etc. to become
entangled in the lift while platform is being raised or lowered.
• DO NOT override, alter,or bypass safety devices.
• DO NOT use boom rotation for pushing or pulling.
• DO NOT exceed platform capacity when transferring loads to the platform while elevated.
• DO NOT use as a crane for lifting materials.
• DO NOT leave keys in machine while unattended.
• Plug charger in at the end of each day.
• When using the lift with the 110V power cord plugged into the base of the unit, care must be taken to ensure that
the cord is not damaged or entangled during rotation.
• DO NOT allow flames, sparks, or embers near batteries and DO NOT smoke near batteries.Batteries produce a
hydrogen, oxygen gas mixture which can explode.
OWNERS & OPERATORS ARE RESPONSIBLE FOR INSPECTION, MAINTENANCE, TRAINING,
AND OPERATION AS REQUIRED BYTHE OWNERS MANUAL .
IF YOU HAVE NOT BEEN PROVIDED WITH SAFETY LITERATURE,
OR FOR ANY QUESTIONS CONCERNING THE SAFE USE OFTHIS
EQUIPMENT,CALL 419/445-9675.
CFT/RFT B06-00-0145
B06-00-0145
®
COIA/RFT
B06-00-0033
B06-00-0033
THIS UNIT SHALL ONLY BE TOWED
WHEN ALL BOOM SECTIONS ARE
FULLY DOWN AND LOCKED WITH
TRANSPORT SAFETY PINS.
CAUTION
This machine is NOT insulated. Do not use within 10 ft. of power lines
or other electrically charged sources. This machine
DOES NOT provide
protection for personnel from contact with or close proximity to any live
electrical power source and by allshould be considered energized
personnel coming in contact with machine.
IT IS UNLAWFUL TO OPERATE
THIS EQUIPMENT WITHIN 10
FEET OF HIGH VOLTAGE LINES
OF 50,000 VOLTS OR LESS.
For safe clearance of lines in excess of 50,000 volts, see owners manual.
CFT/RFC B06-00-0146
B06-00-0146
DANGER
B06-00-0290
B06-00-0290
!! ATTENTION !!
To prevent premature motor failure, it is
imperative that the fiberglass cover be
kept in the closed position to protect
against direct contact with any foreign
particles and/or moisture. Should the
hydraulic power unit need to be cleaned,
it is very important to cover or shield the
motor. The DC motor must not come into
direct contact with foreign particles and/
or moisture. See Operator’s Manual for
details.
B06-00-0261FFU
B06-00-0261
This machine is designed and manufactured in compli-
with the ANSI A92.2 standard in force on the date of
manufacture. Dealers, owners, users, operators, lessors,
and lessees are responsible for inspection, maintenance,
training, and operation as required be A92.2 and the owners
m
Alterations, modifications, or changes to this machine
without the written authorization of Workforce Products,
Inc. as well as any unauthorized adjustment of values,
disabling or by-passing of safety devices or the improper
use of this machine shall exempt Workforce Products, Inc.
from any liability for any resulting injuries or damage.
CAUTION
anual.
B06-00-0243
GASOLINE FILL
DANGER
BEFORE USING: EXTEND, LOCK, STABILIZE
OUTRIGGERS; AND LEVEL MACHINE.
DANGER
CFT/RFC B06-00-0139
B06-00-0139
1. Read and follow all manuals and
decals.
2. Disconnect the boom hitch from the
towing vehicle.
3. Extend lock and base all four (4)
outriggers.
4. Level the lift using the four (4)
outriggers and by referencing the T-
level located at the front of the boom
power base. Remove as much
weight as possible from the trailer
tires.
5. Always wear safety harness and
attach lanyard when operating from
the basket.
BOOM OPERATING INSTRUCTIONS (PROPORTIONAL CONTROLS)
B06-00-0376
B06-00-0376
ITT
6. If using gas model, start engine from either
the lower or upper control box. It may be
necessary to hold the choke for a short
time when engine is cold. If using DC
model, turn master power switch to “on”.
Familiarize yourself with the operation of
the lift, using the ground controls before
operating the lift from the platform.
7. On the lower control panel, position
“control selector” switch to “upper”.
The lift is now ready to operate from the
basket.
8. Select function by pressing and holding
button. Grasp the handle and slowly
squeeze the trigger. Boom speed
increases the harder the trigger is
squeezed.
EMERGENCY CONTROLVALVE
B06-00-0006
B06-00-0006
LUBRICATE
SEMI-ANNUALLY
COIA B06-00-0037
LUBRICATE
WEEKLY
COIA B06-00-0036
B06-00-0037
B06-00-0036
SAFETY
HARNESS
LANYARD
ATTACHMENT
POINT
B06-00-0173UFC
B06-00-0173
B06-00-0151
B06-00-0151GFT/LFG
DANGER
110 VOLT
Figure 5-1. Replacement Decals, Sheet 1 of 3