Using the System Control Manager 8-19
Table 82 Status Command Fields (Continued)
Field Meaning
OCP power switch:
OCP halt:
OCP secure:
Indicates the position of the control panel keyswitch
and Halt button. In this case, the keyswitch is in the
Off position and the Halt button is not pushed in. The
OCP is in a nonsecure state.
Remote access: Remote access to the system is disabled or enabled.
Remote user: A remote user is either not connected, as in the
example, or connected.
Alerts: Alert status is reported: Enabled or Disabled. Possible
alerts are listed in Section 8.7.6.
Modem password: The modem password is displayed.
Modem init string:
Modem initialization string set by the set init
command.
Modem dial string:
Modem dial string, set by the set dial command.
Modem alert string:
Modem alert string, set by the set alert command.
Alert pending: Yes = Alert has been triggered.
No = No alert has been triggered.
Most recent alert: Tells the cause of the most recent alert.