A SERVICE OF

logo

DS6400
4
4.2.2 PackTrack™ Calibration for DS6400 Oscillating Mirror Models
The DS6400 oscillating mirror models can be used in PackTrack™ operating mode only
when the scanner is mounted so that the
scan line is parallel to the conveyor direction as
shown in the following figure:
Conveyor
Direction
Scan
Line
Figure 83 – Oscillating Mirror Models in PackTrack™ Mode
PackTrack™ Calibration must be made while the
scanning plane is perpendicular to the
conveyor plane and fixed (not oscillating).
4.3 PERFORMANCE
The scan rate is 800 scans/sec.
Refer to the diagrams in par. 4.4 for further details on the reading features. These diagrams
are taken on various resolution sample codes at a 25 °C ambient temperature depending on
the conditions listed under each diagram.
4.3.1 Reading Conditions
ANSI Grade B minimum
800 scans/sec
The following tables describe the requirements for standard applications.
Minimum Code Height for ACR Reading (mm)
45° 30°
Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3
0.25
10 12 14 16 18 20 7 9 10 12 13 15
0.30
12 14 15 17 19 21 8 9 11 12 14 15
0.33
13 14 16 18 20 22 8 10 11 13 14 16
0.38
14 16 18 19 21 23 9 11 12 14 15 17
0.50
18 19 21 23 25 26 11 12 14 15 17 18
0.72
24 25 27 28 30 32 15 16 17 19 20 22
2/5 Interleaved
Code Resolution
(mm)
1.00
33 34 35 36 38 40 20 21 22 23 25 26
Ratio 3:1
Table 1
70