A SERVICE OF

logo

30 About Your System
E1714 Unknown error.
Review & clear
SEL.
The system BIOS has
determined there has
been an error in the
system, but is unable to
determine its origin.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 167.
E171F PCIe fatal
error on Bus
## Device ##
Function ##
The system BIOS has
reported a PCIe fatal
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.
E1810 Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 156.
E1812 Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920 iDRAC6 Upgrade
Failed.
optional iDRAC6
upgrade has failed.
See "Troubleshooting
Expansion Cards" on
page 159.
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 167.
Table 1-2. LCD Status Messages (Optional) (continued)
Code Text Causes Corrective Actions
book.book Page 30 Tuesday, March 31, 2009 5:26 PM