* Included with the tool.
Before operating the tool check the following:
q Inspect tool for damage or leaking oil.
Do not use tool if damaged or leaking oil.
q Check to see that correct nosepiece is installed into the nose housing.
Tighten nosepieces to 60-65 in-lbs. of torque.
q Be sure that the nose housing nut (9) is tight.
Hand tighten only.
q Connect tool to air supply.
See air supply requirements (page 4).
q Turn on MCS by rotating switch-ring to one of the three ‘ON’ positions.
MCS style only.
q Adjust low-flow vacuum setting if necessary.
See “Adjusting low-flow vacuum” (page 8).
q Insert rivet into nosepiece.
q Position rivet in work piece.
q Pull trigger to set rivet.
When turned on, the MCS vacuum will automatically switch to high-flow mode and
transfer the mandrel into the collector bottle.
q Release trigger.
MCS low-flow will begin to time out. (Approx. 5 to 18 seconds).
Closed End T-Rivet HR Rivets
Rivet Diameter Open End
Steel
Mandrel
Aluminum
Mandrel
Aluminum
Body
Steel
Body
3/32” (2.4 mm) PRN314 - - - - -
1/8” (3.2 mm) or
7/64” (2.8 mm)
PRN414
*
PRN424 PRN434 - PRN414 PRN4H
5/32” (4.0 mm) PRN514
*
PRN524 PRN534 - PRN514 PRN5H
3/16” (4.8 mm) PRN614
*
PRN624 PRN634 PRN625 PRN614 -
Common Nosepieces
Basic Tool Operation