CH-A 1
Loop A connection 1. This is a SFP fibre channel connector used to connect to a
host system or to an expansion chassis for Loop A.
CH-A 2
Loop A connection 2. This is a SFP fibre channel connector used to connect to a
host system or to an expansion chassis for Loop A.
CH-B 1
Loop B connection 1. This is a SFP fibre channel connector used to connect to a
host system or to an expansion chassis for Loop B.
CH-B 2
Loop B connection 2. This is a SFP fibre channel connector used to connect to a
host system or to an expansion chassis for Loop B.
System Fault Audible Alert
A system fault includes over temperature, power fault, or blower fault. The
buzzer will sound off with a sequence of beeps to indicate the fault that has
occurred.
2 beeps = Temperature Fault
3 beeps = Blower Fault;
5 beeps = Power Supply Fault.
Alarm Reset
This button will turn off the audible alert. Pressing this button will not reset
power to the unit, it will only silence the alarm.
FORTRA
Force
4
G6 Installation Guide Rev B
4-5
CH B 2
CH B 1
Alarm Reset
Button
CH A 1 CH A 2
AC Input
Power
On/Off