This chapter covers the operations of the power supply for FORTRA
FFoorrccee
44
G6 units. For operation, the AC cord (included) must be connected to the AC
Inlet at the back of the unit, and the On/Off switch must be switched ON. The
Status LED on the power supply will light to indicate the power supply is
functioning properly. If the power supply experiences a problem and cannot
operate within its normal specifications, the Status LED will light ‘Red’ and an
audible alert will sound. Pressing the Alarm Reset button located on the back of
the unit will turn off the audible alert.
Power Supply Removal/Insertion
Follow the following steps to remove a power supply in a 4-bay unit.
1. Unlock the unit (see Chapter 3 for Device
Installation instructions) & open the handle
by pulling out. This action will disconnect
the supply canister from the unit.
2. Grab the handle and pull straight out.
3. Carefully remove the supply from the unit. It is ok to grab the sides of
the supply to fully remove it.
Reverse the steps to reinstall the power supply.
FORTRA
Force
4
G6 Installation Guide Rev B
6-1
Handle
Status LED
The Identification
symbol warns the
user that the
canister houses
an electrical
device that should
not be tampered
with.
6. Power Supply Operation