Configuring the Thermal Profile for Fan Tray Operations (APX 8000)
Thermal status reporting
APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide Preliminary May 9, 2000 3-5
Thermalstatus command
The thermalstatus command displays a number of temperature-related values to show
the overall thermal status of the unit. For example, it displays:
• Ambient temperature at fan tray intake.
• Shelf controller temperature.
• High, Low, and Alarm temperature thresholds.
• Slot card temperature for slot cards that support temperature reporting. Currently, no slot
cards support thermal information reporting.
• Power supply thermal status, and whether the power supplies are in an overheated state.
• Fan tray status, including the fan tray operational mode, number of revolutions per minute
at low-noise speed, and current revolutions per minute of each fan.
For example:
admin> thermalstatus
System Thermal status
Ambient temperature at intake : 27 C (80 F)
Shelf controller temperature : 35 C (95 F)
High temperature threshold : 36 C (96 F)
Low temperature threshold : 32 C (89 F)
Alarm temperature threshold : 38 C (100 F)
Slot cards:
(no slot cards contain thermal information)
Power supply thermal status
Power Supply # Temp
=================================
A OK
B OK
C n/a
D OK
Fantray status
Fan operational mode: auto-regulation
Low-noise RPM: 2000
Current fan mode: Full-speed
Fan # RPM Status
============================================
1 3289 GOOD
2 3214 GOOD
3 3075 GOOD
4 3143 GOOD
5 3214 GOOD
6 3289 GOOD