![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/4b/44bc7a96-c146-4448-8e06-1f06bcd5a4be/44bc7a96-c146-4448-8e06-1f06bcd5a4be-bgd.png)
F3S-B
14
RS-- 485(A) (Grey 5)
RS-- 485(B) (Pink 6)
K3
E1
S1
k1
k2
E1
S2: Restart interlock reset switch
S2
Emitter
Emitter
Receiver
k1, k2: Auxiliarycontact to moni-
torthe condition of the finalrelay
24 VDC(Brown 2)
0V(Blue7)
Instability (Yellow 4)
Interlock selection (Yellow4)
24 VDC(Brown 2)
0V(Blue7)
Relay monitoring (White 1)
Ext. test (Green 3)
24 VDC(Brown 2)
0V(Blue7)
When Using START/RESTART FUNCTION When Using Optional R E
Y MONITORING FUNCTION
J DETAILS OF F39-EU1E OPTIONAL FUNCTION KIT
Preparation
Caution
Perform the installation check and the periodical inspection described in the F3S-B manual.
Do not disassemble, repair or modify the F39-E1.
Do not use the F39-E1 in flammable or explosive environments.
!
To use the F39-U1E software, the following items are necessary.
• Personal Computer (not included)
-- Windows 95, Window s 98, or Windows NT
-- 133MHz Pentium processor or better
-- 32MB RAM or hi gher for Windows 95 and Windows 98
-- 64MB RAM or hi gher for Windows NT
-- A 115kBd RS-232 serial interface port or better
• F39-E1 Interface Unit
114
8
35
60
• F39-JB1C Interface Cable 5 m cable length,
M8 connector (4 pins)
30.5 5000
Round vinyl--insulated cord
5 mm dia. (32/0.1 mm dia.) 4cores
∅ 15
• RS -232C Cable (not included)