![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/4b/44bc7a96-c146-4448-8e06-1f06bcd5a4be/44bc7a96-c146-4448-8e06-1f06bcd5a4be-bg4.png)
F3S-B
5
Specifications Table -- continued from previous page
Type
F3S-BjjjP(SeeNote1)
Stand-Alone
F3S-BjjjPjj (See Note 1)
Master Unit for series connection
F3S-Bjjj (See Note 1)
Master Unit for series connection
Protective height 300 / 450 / 600 / 750 / 900 / 1,050 / 1,200 / 1,350 / 1,500 / 1,650 mm 300 / 450 / 600 / 750 mm
Detection distance 0.3to5.0m
Response time ON to OFF: See t able Response Time
OFF to ON (See note 2): Default 100 ms (selectable w ith F39--U1E, 80 to 400 ms)
Startup waiting time 2smax.
Supply voltage: Vs 24 VDC ±20% (including 5 Vp-p ripple)
Current consumption 400 mA max. (under no-load condi tions)
Light source Infrared LED (880 nm wavelength). Lifetime: 50,000 hrs. at 25 °C.
Effective aperture angle Within ±5° for t he em itt er and receiver at a detection di stance o f a t least 3 m a ccording t o I EC 61496--2
Operating mode Light ON
Control output Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max. (except for voltage drop
due to cable extension)
Instability output PNP transistor output (not safety--related control output),
activated during an insufficient light detection, failure detection and connection with F 39--E1,
load current 100 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension)
Protection circuit Output short--circuit protection, power supply reverse connection protection
function
ctive: No connection or 0 to 2.5
DC
3m
max.
.
,
.
Inactive: Instabilit
out
ut line
Resetofstart
restart interlock b
connectin
Interlock selection in
ut line to:
Interlock reset: 17 VDC to Vs, 20 mA max. Duration time 15 to 2,500 ms
External test function Mode selection b
connectin
E
e
na
es
n
u
line to:
Active: 17VDCtoVs,10mAmax.Durationtimeatleast15ms
,
.
Inactive: No connection or 0 to 2.5 VDC, 2 mA max.
--
function
o
tional
,
--
Rela
monitorin
in
ut line with NC contact connected
vailable level: 17 VDC to
s
10 m
ma
.
,
.
llowed rela
dela
time: Selectable between 20 and 300 ms
SeeNote2
Termination when not selected: No connection or 0 to 2.5 VDC, 2 mA max.
Start interlock function
(optional)
Default inactive, sel ectable with F39-U1E
Blanking function
(optional)
Default inactive, sel ectable with F39-U1E
Indicator See Indicators No Indicators
onnect
on met
o
or
xtens
on ca
e:
p
ns,
connector.
or
er
es connect
on ca
e:
p
ns,
connector
Ambient temperature During operation: -10 to 55 °C (with no freezing)
During storage: -25 to 70 °C
Ambient humidity During operation: 35 to 85 %RH (with no condensation)
During storage: 35 to 95 %R H
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength
voltage
1,000 VAC 50/60 H z for 1 min
Degree of protection IEC60529 IP65
Vibration resistance Normal operation: 10 to 55 Hz, double--amplitude: 0.7mm, X, Y and Z directions 20 sweeps
Shock resistance Normal operation: 100 m/s
2
[10 G], X, Y and Z directions: 1000 times
Materials Case: Aluminum
Front cover: PMMA (acrylic resin)
End caps: PA6
Size (cross-section) 30 x 40 mm
Accessories Test rod (See Note 3); mounting brackets -- top and bottom, mounting brackets -- intermediate (See Note 4);
mounting plates (See Note 4); instruction manuals (See N ote 5).
Applicable standards IEC(EN)61496-1 Type 2 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2 Type 2 AOPD (Active Opto-Electronic Protective Devices)
Note:
1
For detailed type names and optical specifications, see Ordering Information.
2
Nominal value (set time). The accuracy is --0. +70% of the ON to OFF response time.
3
Only with F3S--Bjjj2P and BMjjj2Pjj
4
For the 1,050 mm protective height and longer types.
5
Only with F3S--BjjjPj and BMjj2Pjj.