![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/db/8db68f42-c49b-40b7-bb18-b74ffc84ed68/8db68f42-c49b-40b7-bb18-b74ffc84ed68-bgb.png)
START-UP
When you connect to a Stingray for the first time follow this procedure:
1. Use
Communication/Connection Setup to configure your PC for communications.
2. Use
Real Time Monitor to configure the logging frequency and click Write to initialize logging,
date and time. Date and time are read by the Stingray from your PC.
3. Use
Retrieve DataLog to download log files from a Stingray.
CONNECTION SETUP
Configure communications with the Stingray
through the
Communication menu.
Select
Connection Setup.
Refer to the Greyline Logger Help file
for detailed instructions. Select the
Connection Type according to your PC
setup.
Use
Standard PC serial port if your PC or
laptop has an RS232 port, otherwise use
a USB to RS232 converter and select
USB Using virtual com port.
Stingray baud rate is fixed at 28800 and Greyline Logger baud rate must be set at 28800 to match.
Modem Settings are only required if you will connect to a Stingray through modems and telephone lines.
Refer to the Greyline Logger
Help for more detailed instructions.
Stingray Level-Velocity Logger
Manual Series A.3