ERA & EBD SERIES ELECTRIC FRYERS - GENERAL
KLEENSCREEN FILTRATION
SYSTEM
The Kleenscreen filtration system is integrated into
the ERA & EBD Series fryer battery. The filter is
housed in a pull-out drawer assembly at the base of
the fryer. The filtering components in the drawer
include a stainless steel filter tank, crumb-catch
basket and a dual element mesh filter screen. With
the filter drawer closed, a self-seating oil return line
provides the path to return the filtered shortening to
the fry tank.
This system is designed to provide a thorough and
easy method to filter the shortening.
Some of the benefits include:
• Self-contained system eliminating the use of
external filter equipment.
• Paperless filtering system.
• Easy to clean and low maintenance.
Kleenscreen fryer batteries are available in a
minimum of two and a maximum of four fryer
sections. The fryer size of each section is identical.
A GRO Frymate (dump station) can also be included
as one or more of the sections.
SPECIFICATIONS
MODEL
KW
PER
FRYER
SECTION
AMPS - EACH FRYER
SECTION
(3 PHASE/ 60HZ)*
PER LINE
208V 240V 480V
ALL 50 LB
CAPACITY
FRYERS
14 39 34 17
17 47 41 20
ALL 85 LB
CAPACITY
FRYERS
24 67 58 29
NOTES:
* Amperage values in the table are
nominal. Tolerance is +5/-10%.
Single Floor Model Fryers
• 208VAC, 240VAC or 480VAC (3 phase, 60HZ)
to power the heating elements.
Drawer Filter System
Separate electrical connections are required for
each
section of the battery.
• 208VAC, 240VAC or 480VAC (3 phase, 60HZ)
to power the heating elements.
• On 208VAC and 240VAC models, a
transformer provides power for the fryer
controls and drawer filter system controls.
• On 480VAC models, a 120VAC connection is
required for each fryer section.
TOOLS
Standard
• Standard set of hand tools.
• VOM with A/C current tester (any quality VOM
with a sensitivity of at least 20,000 ohms per
volt can be used).
• Digital Temperature tester (thermocouple type).
Special
• Field service grounding kit (available locally).
• Burndy pin extraction tool RX2025 GE1;
Newark Electronics Catalog Number 16F6666.
Used for removing pin terminals on Burndy
connectors.
• Clamp on type amp meter.
F25385 (May 2010)
Page 4 of 32