A SERVICE OF

logo

8 - 61
+
ELEC
IMMOBILIZER SYSTEM
2. The multifunction display is not indicated.
YES
NO
1. Voltage
Connect the pocket tester (DC 20 V) to the
meter assembly couplers as shown.
Positive tester probe
red/green
1
and red/white
3
Negative tester probe
black/white
2
Turn the main switch to ON.
Measure the voltage (DC 12 V) meter
assembly couplers (wire harness end).
Is the voltage within specification?
Replace the meter
assembly.
The wiring circuit
from the main switch
to the meter assem-
bly couplers is faulty
and must be
repaired.
Dg
G/L
R/W
Ch
R/G
Y
B/W
Lg
G/W
Y/L
Ch R/G
Y
G
G/L
R/W
G/W
Y/L
B/W
Lg
1
2
3