Sony CMD-Z28 Cell Phone User Manual


 
7
CABINET (UPPER)
CABINET LOWER
Note: Follow the disassembly procedure in the numerical order given.
SECTION 4
JIGS AND TOOLS
Description Part No. Remark
DATA TRANSFER JIG 1-792-172-11 NECESSARY FOR SOFTWARE UPDATE
HOOK RELEASE JIG 3-043-180-01 FOR HOUSING OPENING
TESTER CONNECTION CABLE 1-792-726-11 FOR CONNECTION TO GSM MEASURE EQUPMENT
1
two screws
2
three claws
4
three claws
5
cabinet (upper)
2
four claws
3
2
flexible PWB unit
ground terminal point of contact
Note 1: Do not touch the ground point of contact
on the flexible PWB unit.
Note 2: Do not make the ground point of contact
get into the holder (vibration).
Note 3: Clean the ground point of contact
with alcohol by cotton fixed to a stick
when it is touched by greasy hands.
3
cabinet (lower)
1
holder (vibration)
DATA TRANSFER JIG
HOOK RELEASE JIG
TESTER CONNECTION CABLE
SECTION 5
DISASSEMBLY