Sony Ericsson T226 Cell Phone User Manual


 
T226 White Paper
July 2003 (Rev C)
49
Parameter set list Name
Startpage
IP settings:
CSD phone no., CSD Data rate, CSD dial type
GPRS APN, password request, allow calls, authentication, data
compression, header compression, quality of services
IP address, datamode (conn.less or oriented)
UserId and password
Security on/off
Show images on/off
Response timer
Manual selection Yes, between Analog (V32) and Digital (V110)
Parameter sets include WAP/CSD, WAP/GPRS (different sets)
Factory pre-configuration WAP/CSD (possibility to lock a setting), WAP/GPRS
OTA WAP/CSD, WAP/GPRS configuration possible
Simultaneous OTA WAP/CSD, WAP/GPRS configuration possible
Single OTA WAP/CSD, WAP/GPRS is not possible
Bookmarks Not empty by default
URL format Underlined
Security mechanism
OTA provisioning (if empty) Operator verification through a code, included in the OTA data. This
code is shown to the user who can choose installation or not.
Interface (if empty) An Install question is asked with the code, if available.
The user has to choose if a new WAP profile shall be created or an
existing profile shall be replaced.
Re-provisioning (Set 1 filled) As above
Interface (Set 1 filled) As above
Carrier reset/provisioning Yes, but not if the set is pre-configured in the factory and locked.
SWIM Not used for provisioning.
The SWIM is only used for WAP security, both WTLS connections and
digital signatures.
SWIM certificate Both client and trusted certificates can be used for WTLS connections
and digital signatures.
No new certificates can be stored and no old ones can be removed by the
terminal.
Additional provisioning
Preferred bearer customization Yes
Email customization No
Other applications/features Yes, MMS
Technologies
WAP Forum OTA provisioning Yes
Feature Support in the T226 for WAP