Installing and Configuring the Line Unit
Campus-RS Line Unit User Manual May 29, 2002 13
SET THE HDSL OPERATING MODE AND
T
RANSMISSION RATE
This section provides generic instruction for setting the HDSL Operating
Mode and transmission rate. The actual steps depend on the interface card
mated with the Line Unit. Refer to the manual for the interface card for a
description of configuration options and complete configuration instructions.
The steps in this section use the menu buttons and LCD on the Campus-Star’s
Campus Management Unit (CMU). To set the HDSL Transmission Rate:
1 Use the Slot selection buttons to select the slot in which you installed the
Line Unit. The LCD displays:
MARGIN (LOC/RMT)
1:XX/XX 2:XX/XX
2 Press Escape four times to go to the top level menu.
3 Press Next until HDSL LINK CONFIG & STATUS displays, then press
Enter.
4 Continue with one of the following sections, depending on whether you
are using Standard Mode or Extended Mode.
CMU-710 MANAGEMENT UNIT
SLOT
RESETPOWER
RS-232
ALARMS
MAJOR
MINOR
ACO
Menu buttons
Console port Reset button
LCD display Slot selection control pad System alarm LEDs
NEXT ENTER ESC
1061.book Page 13 Wednesday, May 29, 2002 8:59 AM