Sharp, EIKI EIP projectors (Code 20 hex, absolute audio)
This family has many members with a range of channel messages.
Sharp has RS232 code charts at the back of the Operation Manual for each projector.
Channel codes are:
Computer1 := 'IRGB 1' + 0D; // RGB 1 VGA analog-RGB
Computer2 := 'IRGB 2' + 0D; // RGB 2 analog, sometimes DVI analog
Computer3 := 'IRGB 3' + 0D; // DVI Analog
Computer4 := 'IRGB 4' + 0D; // DVI Digital
Video1 := 'IVED 1' + 0D; // Comp Video/S-Video / Component 1
Video2 := 'IVED 2' + 0D; // S-Video / Comp Video / Component 2
Video3 := 'IVED 3' + 0D; // Comp Video 2
Video4 := 'IVED 4' + 0D; // S-Video 2
Video5 := 'IVED 5' + 0D; // RGB/COMPONENT on SHARP DT-400, XV-Z2000, EIKI EIP-1500
Video6 := 'IVED 6' + 0D; // DIGITAL MODE on SHARP DT-400, XV-Z2000, EIKI EIP-1500
Video7 := 'ISEV 1' + 0D; // S-VIDEO on EIKI_EIP_S200/X200/X350
Video8 := 'ICMP 1' + 0D; // COMPONENT on EIKI_EIP_S200/X200/X350
Video9 := 'IDVI 1' + 0D; // DVI on EIKI_EIP_S200/X200/X350
Any one of these codes can be set into Constant:0/Constant:1 for computer codes and Constant:2/Constant:3 for video
codes. (The default is to have Computer1 (above) as the “Computer” channel and Video1 as the “Video” channel.
Setting OPT1 switch ON will swap Video1 and Video2 channels.)
Some models use IVED 1 for Comp Video, and IVED2 for S-Video, and some use the reverse;
OPT7 handshake mode and power on panel connection blink codes available.
RS232 connections to Sharp/Eiki projectors
These use a D-sub 9-pin connector, female or male on cable: (May be via an adaptor cable from projector 9-pin mini-
DIN) Communications is at 9600 baud 8N1. Some projectors may need this to be set up via an on-screen menu.
Function/Direction T440 “projector”
Connection
Sharp Control Port
Connector, D-sub 9
Sharp Control Port
Connector DIN 9
Ground Ground 9-pin D-sub pin 5 9-pin D-sub pin 5
Data from T440 to projector Tx 9-pin D-sub pin 2 9-pin D-sub pin 2
Reply data from projector to T440 Rx 9-pin D-sub pin 3 9-pin D-sub pin 3
Plus 9 volt CTS/DTR to projector CTS unused unused
After installation wiring of any projector to a T440, use a multimeter to check voltages of –9 on BOTH TX and RX pins