Specification
(STANDARD)
DLE DC4 fn a b (fn = 2)
[Name] Execute power-off sequence
[Format] ASCII DLE DC4 fn a b
Hex 10 14 fn a b
Decimal 16 20 fn a b
[Range] fn = 2
a = 1
b = 8
[Description] Executes the printer power-off sequence and transmits the power-off notice.
Stores the values of the maintenance counter.
Sets the interface to BUSY.
Sets the printer to standby mode.
[Notes] Take the following into consideration:
If the received data includes a data string matching this command, the printer
performs the command. Users must consider this.
For example: Graphic data might accidentally include a data string matching this
command.
Do not embed this command within another command.
For example: Graphic data might include this command.
This command does not shut the power off. The operator must turn off the power
after receiving the power-off notice.
If this command is encountered, the printer will not continue to process anything. To
recover the printer to print again, it is necessary to turn the power on again or execute
a hardware reset.
[Reference] Appendix G