Removal and replacement procedures 45
Remove the component as indicated.
To replace the component, reverse the removal procedure.
Hard drive cages and backplanes
The server supports the following hard drive cages and backplanes:
• Two-bay LFF drive cage (on page 45)
• Six-bay LFF backplane (on page 47)
• Eight-bay SFF drive cage backplane (bay 1) (on page 48)
• Eight-bay SFF drive cage backplane (bay 2) (on page 49)
• Eight-bay SFF drive cage backplane (bay 3) (on page 51)
For jumper settings, see "Drive cage jumper location and configuration settings (on page 98)."
Two-bay LFF drive cage
To remove the component:
1. Power down the server (on page 27).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Tower bezel" on page 30).
o Extend the server from the rack (on page 28).
3. Remove the access panel ("Access panel" on page 31).
4. Remove fan 5 ("Fan 5" on page 31).
5. If installed, remove the BBWC battery pack or the FBWC capacitor pack ("BBWC battery pack or
FBWC capacitor pack" on page 33).
6. Remove the air baffle ("Air baffle" on page 34).
7. Remove the fan cage ("Fan cage" on page 35).