A SERVICE OF

logo

Attention: In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply and to install and remove a dc power supply. See the
documentation that comes with each dc power supply.
7. Turn on the server. You can now start the Configuration/Setup Utility program
and either delete the old password or set a new power-on or administrator
password.
8. Save the configuration and turn off the server; then, disconnect all power cords
and external cables again.
Attention: In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply and to install and remove a dc power supply. See the
documentation that comes with each dc power supply.
9. Remove the cover, move the clear-CMOS switch back to the Off position, and
reinstall the cover.
10. Replace the server in the rack and connect the external cables and power
cords; then, turn on the server.
Attention: In a dc power environment, only trained service personnel other
than Lenovo service technicians are authorized to connect or disconnect power
to the dc power supply and to install and remove a dc power supply. See the
documentation that comes with each dc power supply.
Using the RAID Configuration Utility program
Use the RAID Configuration Utility programs to perform the following tasks:
v Configure a redundant array of independent disks (RAID) array
v View or change the RAID configuration and associated devices
When
you are using the RAID Configuration Utility programs to configure and
manage arrays, consider the following information:
v Hard disk drive capacities affect how you create arrays. Drives in an array can
have different capacities, but the RAID controller treats them as if they all have
the capacity of the smallest hard disk drive.
v To help ensure signal quality, do not mix drives with different speeds and data
rates.
v To update the firmware and BIOS code for an optional ServeRAID SAS
controller, you must use the IBM ServeRAID Support CD that comes with the
ServeRAID controller.
Starting the RAID Configuration Utility program
To start the IBM ServeRAID Configuration Utility program, complete the following
steps:
1. Turn on the server.
2. When the prompt <<< Press <CTRL><A> for IBM ServeRAID Configuration
Utility! >>> appears, press Ctrl+A. If you have set an administrator password,
you are prompted to type the password.
3. To select a choice from the menu (see “RAID Configuration Utility menu
choices” on page 88), use the arrow keys.
4. Use the arrow keys to select the channel for which you want to change settings.
5. To change the settings of the selected items, follow the instructions on the
screen.
Chapter 3. Configuring the server 87