A SERVICE OF

logo

u
Transfer top and bottom
fastening screws
Fig. 2 (2)
to the opposite side.
Screws are self-tapping. Use
cordless screwdriver:
u
Unscrew
Fig. 5 (7)
the
hinges from the door,
transfer them diagonally and
screw them firmly into place
(with 4 Nm).
u
Close the vacated fastening
holes with the accompa-
nying stoppers
Fig. 5 (6)
.
Fig. 5
2.2.5 Re-fit soft stop mechanism*
Fig. 6
u
Screw the ball stud
Fig. 6 (3)
firmly into the new fastening
hole (with 4 Nm) (Torx® 25).
u
Push tension spring
Fig. 6 (11)
inwards again.
u
Screw on the bracket
Fig. 6 (1)
tightly (3 Nm)
anschrauben.
u
Attachsoft stop mechanism
Fig. 6 (2)
to ball stud.
2.2.6 Re-fit door
u
Attach appliance door to the prefitted fastening screws
Fig. 2 (2)
.
u
Firmly tighten the fastening screws
Fig. 2 (2)
(with 4 Nm).
u
Re-fit covers
Fig. 2 (1)
.
WARNING
Risk of injury due to the door dropping out!
If the fastening parts are not screwed into place firmly enough,
the door may drop out. This may lead to severe injuries. What
is more, the door may not close and therefore the appliance
may fail to cool properly.
u
Screw the hinges and the ball journal of the soft stop mecha-
nism firmly into place, with 4 Nm.
u
Screw the holder of the soft stop mechanism firmly into
place, with at least 3 Nm.
u
Check all of the screws and retighten if necessary.
2.3 Built-in
All the assembly components accompany the appliance.
Fig. 7
Ensure that the following tools are to hand:
q
Cordless screwdriver Torx®15, 20, 25
q
Spanner 13
q
Screwdriver Torx® 15
q
Flat-blade screwdriver 6
q
Allen key 8
NOTICE
Risk of damage due to condensate!
u
If refrigerator and freezer are installed side-by-side, the
freezer always has to be sited to the right of the refrigerator
(as seen from the front). Condensate is prevented from
forming between the appliances by the foamed-in side wall
heating on the left side of the freezer.
In the case of side-by-side installation, freezer and refrigerator
next to one another, build the appliances into separate built-
under recesses.
Pay attention that the socket is readily accessible.
Check installation dimensions:
Putting into operation
4