![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/73/673ad372-630a-4585-a945-a2393b01adc9/673ad372-630a-4585-a945-a2393b01adc9-bg23.png)
33
AUTOMATION OUTPUT MODE DURING ALARM
✦ The factory setting causes the Automation
Output to fl ash if it is programmed to activate
during or after an alarm.
✎ NOTE: For the Automation Output to activate
during or after an alarm, that function must be
enabled with Programming Step 71 or 72.
STEP #68 The output can be programmed to be a steady
output using this step.
AUTOMATION ACTIVATION TONE
✦ The factory setting causes the keypad(s) to
sound a “Bing” when the Automation Output is
activated by pressing the
key, or when it's
triggered with a two-button remote control.
STEP #69 This sound can be silenced using this step.
REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP
✦ When arming with the portable remote control
or with a hardwired loop programmed as arm/
disarm (sensor Function #9), the factory setting
causes the keypad(s) to “chirp” once when
armed, twice when disarmed, and three times
when arming with sensors bypassed.
STEP #70 These chirps can be silenced using this step.
✎ NOTE: If these chirps are silenced, it is
recommended to program the Automation Output
to be active when the system is armed, so a light
can be triggered displaying the arming status of
the system.
AUTOMATION OUTPUT ON DURING AND AFTER ALARM
✦ The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button
remote control.
STEP #71 The Control Panel can be programmed to
activate the Automation Output during and after
any alarms as well as when normally triggered
using this step.
✎ NOTE: The output will continue until the fl ashing
sensor status lights are cleared.
AUTOMATION OUTPUT ON DURING ALARM
✦ The factory setting causes the Control Panel's
Automation Output to activate when pressing the
key, or when it's triggered with a two-button
remote control.
STEP #72 The Control Panel can be programmed to
activate the Automation Output during alarms as
well as when normally triggered using this step.
✎ NOTE: The Automation Output can be programmed
to fl ash or be steady during alarm, see
Programming Step 68.
PROGRAMMING STEP #68
ENTERS STEP NUMBER
0 FOR FLASHING OUTPUT
1
FOR STEADY OUTPUT
STORES VALUE - 1 BING
PROGRAMMING STEP #69
ENTERS STEP NUMBER
0 FOR BING TONE OFF
1
FOR BING TONE ON
STORES VALUE - 1 BING
PROGRAMMING STEP #70
ENTERS STEP NUMBER
0 FOR CHIRPS OFF
1
FOR CHIRPS ON
STORES VALUE - 1 BING
PROGRAMMING STEP #71
ENTERS STEP NUMBER
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING &
AFTER ALARM
STORES VALUE - 1 BING
PROGRAMMING
STEP #72
ENTERS STEP NUMBER
0 FOR STANDARD TRIGGER
1
FOR OUTPUT DURING ALARM
STORES VALUE - 1 BING