![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/73/673ad372-630a-4585-a945-a2393b01adc9/673ad372-630a-4585-a945-a2393b01adc9-bg9.png)
7
1 BATTERY FUSE
★ Type 2AG, 3-amp fuse for the backup battery.
★ If the keypad's POWER light is fl ashing and the optional backup battery is
installed and charged, check this fuse.
✎ WARNING: For continued protection against the risk of fi re, replace only
with the same type and rating of fuse.
2 CONDUIT KNOCKOUTS
★ Four cabinet knockouts are provided for wiring using conduit.
★ The 3/4" knockouts fi t standard 3/4" conduit fi ttings.
3 WIRING ACCESS SLOT
★ Provides access for wiring through a hole in the mounting wall.
★ Route cables for power, telephone, external speaker, etc. through this slot.
4 MAIN TERMINAL BLOCK
★ Terminals for hardwired loop inputs.
★ Terminals for Automation Output to connect to an automation controller.
★ Terminals for external relay output for “dry” contacts (Form C, normally open/
normally closed, 1 amp @ 24 volts maximum).
★ Terminals for fused auxiliary 12 volt output and common ground.
★ Terminals for connection to one or two Model DUAL 824KP keypads.
★ Terminals for connection to the plug-in AC transformer.
5 AUXILIARY FUSE
★ Type 2AG, 1-amp fuse.
★ Protects the auxiliary power output and siren driver circuit.
★ Fuse will blow when load exceeds 1 amp total.
✎ WARNING: For continued protection against the risk of fi re, replace only
with the same type and rating of fuse.
6 TELEPHONE TERMINAL BLOCK
★ Provides telephone connections for the digital communicator.
★ Provides telephone connection for voice prompted telephone remote control
(optional VB-2 digital voice response module required).
★ Provides seized ring and tip connections for local telephone instruments.
Communicator will disconnect local telephones while on-line.
7 WALL-MOUNT KEYHOLE SLOTS
★ Four slots used when mounting Control Panel to the wall.
★ Used as a template for the Control Panel when it is mounted to the wall.
8 DIGITAL VOICE RESPONSE MODULE (OPTIONAL)
★ The Model VB-2 gives the Control Panel's digital communicator listen-only,
manual 2-way and full duplex 2-way audio capability with the Central Station.
★ The module allows remote command of the system using a standard pushbutton
telephone, on or off site.
★ The module provides optional voice prompts from the keypad(s) (Model RSM-2
speaker/microphone kit required for each keypad).
9 ANTENNA KNOCKOUT
★ A cabinet knockout is provided for mounting an external antenna connector.
★ For an external antenna, use Linear's Model LA-P antenna kit.
★ The antenna kit can also be used to connect the Control Panel to co-ax for a
remote antenna.
10 ANNUNCIATOR VOLUME CONTROL
★ Varies the volume of the advisory tones that come from the keypad(s) speaker
when the Model RSM-2 speaker/microphone kit is installed in the keypad.
★ Does not affect keypad's sirens (they are always full volume).
11 RADIO TEST POINTS
★ Used to monitor the Control Panel's radio receiver during troubleshooting.
★ Provides connection for an audio amplifi er to listen to the receiver's output.
★ Helpful to determine sources of radio interference.
12 ANTENNA TERMINALS
★ Antenna and shield (ground) terminals for receiving signals from the system's
sensors.
★ Pre-wired to the Control Panel's internal wire dipole antenna.
★ Alternately connects to the Model LA-P local whip and remote antenna kit.
13 OPTIONAL BACKUP BATTERY
★ Space for 12-volt, 4 amp/hour backup battery. (Highly recommended.)
★ Backup battery is automatically charged and monitored by the Control Panel.
★ Backup battery can power the Control Panel for up to 6 hours.
★ UL NOTE: Normal estimated battery life should be 3 to 4 years.
14 REMOVABLE CABINET COVER
★ The cabinet cover can be removed for easy system wiring and setup.
★ Two screws secure cabinet cover when closed.
★ An optional cabinet lock can be installed for additional security.
5. CONTROL PANEL FEATURES
1
4
5
6
7
8
3
9
10
11
12
14
13
2