![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/73/673ad372-630a-4585-a945-a2393b01adc9/673ad372-630a-4585-a945-a2393b01adc9-bg2d.png)
43
SYSTEM REPORTING CODES
✦ Refer to the System Reporting Codes table to
view/edit the reporting codes for the keypad
FIRE and EMERGENCY buttons and for each of
the three Control Panel conditions. The factory
settings are listed, along with a blank area to
write in the new installation values.
STEPS #261-266
Any value from 0-99 can be programmed for
each event using these steps (enter “0” to stop
an event from reporting).
FORCE ARMING REPORTING CODE
✦ The factory set reporting code for force arming is
“65” (Code 574 with Ademco).
STEP #258 Any value from 0-99 can be programmed for this
event using this step (0 = no report).
✎ NOTE: For force arming reporting, force arming
reports must be enabled. See Page 41.
DURESS REPORTING CODE
✦ The factory set reporting code for Duress is “66”
(Code 121 with Ademco).
STEP #259 Any value from 0-99 can be programmed for this
event using this step (0 = no report).
✎ NOTE: For duress code reporting a keypad duress
code must be programmed. See Page 34.
SYSTEM REPORTING CODES
STEP # PROGRAMMING FUNCTION
POSSIBLE
4 BY 2 VALUES
FACTORY
4 BY 2 VALUES
ADEMCO VALUE
INSTALLATION
4 BY 2 VALUE
258 FORCE ARMING REPORT CODE 0 - 99 65 574
259 DURESS REPORT CODE 0 - 99 66 121
261 SYSTEM FIRE REPORT CODE 0 - 99 68 110
262 SYSTEM EMERGENCY REPORT CODE 0 - 99 69 120
263 SYSTEM TEST/CANCEL REPORT CODE 0 - 99 70 406
264 SYSTEM LOW BATTERY RESTORAL REPORT CODE 0 - 99 71 R302
265 SYSTEM LOW BATTERY CODE 0 - 99 73 E302
OPENING & CLOSING REPORTING CODES TABLE
USER CODE
4 x 2 CLOSING
(ARMING) CODE
4 x 2 OPENING
(DISARMING) CODE
ADEMCO CLOSING
(ARMING) CODE
ADEMCO OPENING
(DISARMING) CODE
MASTER USER CODE1 74 82 R401 C000 E401 C000
RESTRICTED USER CODE #1 75 83 R401 C001 E401 C001
RESTRICTED USER CODE #2 76 84 R401 C002 E401 C002
RESTRICTED USER CODE #3 77 85 R401 C003 E401 C003
RESTRICTED USER CODE #4 78 86 R401 C004 E401 C004
RESTRICTED USER CODE #5 79 87 R401 C005 E401 C005
PAGE ALERT USER CODE (DIALS PAGE NUMBER ONLY, NO CODES REPORTED)
REMOTE/HARDWIRE ARM (SENSOR FCN. 9) & QUICK ARM 81 R407 C007
REMOTE/HARDWIRE DISARM (SENSOR FCN. 9) 89 E407 C007
PROGRAMMING
STEPS #261 - 266
ENTERS STEP NUMBER
0 - 99
FOR SYSTEM
REPORTING CODE
STORES VALUE - 1 BING
PROGRAMMING
STEP #258
ENTERS STEP NUMBER
0 - 99
FOR FORCE ARMING
REPORTING CODE
STORES VALUE - 1 BING
PROGRAMMING STEP #259
ENTERS STEP NUMBER
0 - 99 FOR DURESS CODE
STORES VALUE - 1 BING
Opening & Closing Reporting Codes Table
System Reporting Codes Table