![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/41/8417be3a-d61f-49de-91c8-7e5aa4a20d6e/8417be3a-d61f-49de-91c8-7e5aa4a20d6e-bgd.png)
Stove Installation (for qualified installers only) 13
Travis Industries 93508131 4020327
Mobile Home Requirements
• Outside air must be installed - see "Outside Air Requirements" on page Error! Reference
source not found.11
• Chimney connector and chimney must be one of the following types:
• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney
• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – order an appliance
adapter for the connector being used.
• Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
Minimum Clearance
(See the illustration below)
Reduced Clearance
Connector
A Sidewall to stove 13"
B Backwall to stove 9"
C Cornerwall to stove 7 1/2"
D Connector to sidewall 21 1/2"
E Connector to backwall 11 1/2"
F Connector to cornerwall 16 1/2"
Straight Installations
a
b
d
e
Corner Installations
c
f
NOTE:
Measure clearances to the stove top.
• If using offsets, use the connector clearance listed to the
right, not the connector manufacturer's
clearance.
• The appliance must be secured to the floor (consult your
building official). Secure the outside air boot to the floor
and stove to insure the stove does not dislocate.
• Mobile home installations require a spark arrester at the
chimney termination.
• The appliance must be grounded to the chassis of the
mobile home (consult your building official).
WARNING: DO NOT INSTALL IN SLEEPING ROOM.
CAUTION: THE STRUCTURAL INTEGRITY OF THE
MOBILE HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
12” Min.
Connector Clearance
(as outlined above)
Stove Clearance
(as outlined above)