Specifications
A-3
Other Specifications
Specification Definition
Requirements for
Out-of-
Building Installation
● Installation of a telephone or other standard (tip/ring) device in another building requires the following
In-Range-Out-Of-Building (IROB) protectors to protect the control unit and device from electrical surges:
—System phone: two Lucent Technologies IROB protectors
—System phone: two Lucent Technologies IROB protectors
Wiring
● System phones: Lucent Technologies SYSTIMAX® Bulk Nonplenum (DIW) cable, Lucent Technologies
SYSTIMAX Bulk Plenum (HALAR/HALAR) cable, or at least 2-pair (4-wire) star ("home run" not "loop")
● Other standard telecommunications equipment (single-line phones, fax machines, answering machines, etc.):
1-pair (2-wire) mounting cords (Lucent Technologies D2R mounting cords recommended)
● Bridging adapter: Lucent Technologies 267F2
● Range: 1,000 feet (305 meters) for system phones; 3,000 feet (915 meters) for standard devices
Safety
Requirements
● U.S.: Meets UL 1459 Issue 2
● Canada: Meets CSA C22.2, 225
Government
Approvals and
Local Phone
Company
Information
● U.S.:
FCC Part 68 Key System registration: FCC #AS5USA-61630-KF-E
FCC Part 68 Pooling and Hybrid System registration number: FCC #AS5USA-21213-MF3
Class A:
5-Slot Configuration
2-Slot Configuration with 362EC or PARTNER MAIL VS
Class B:
PARTNER Endeavor Stand-Alone Configuration
REN (outside line jack): 0.9A per line jack
Jack type: RJ11C
Loop start lines
● Canada:
IC CP01, Issue 7
IC registration number (Canada): See the label on the side of the control unit.
IC CS03, Issues 6 & 7
Load Number = 7
Loop start lines