MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Unit Load Calculation Worksheet
Page B-9
Unit Load Worksheet
9. Try to exchange modules between carriers to reduce the unit loads for
slots five and six through 27. (Remember that the 100D, 400 (LS), 400
GS/LS/TTR, 800 GS/LS-ID, 800, 800 NI-BRI, and 800 GS/LS modules
have unit loads of 0.0.) Repeat Steps 1 through 8 to recalculate unit
loads for new configuration.
■ If the exchange reduces the unit load for slots five and six through
27 or less, power is sufficient.
■ If the exchange does not reduce the unit loads for slots 5 and 6
through 27, install wall power units for the appropriate number of
telephones to reduce the unit load to 27.
NOTE:
Empty slots are not permitted between modules.