G36D Zero Clearance Direct Vent Gas Fireplace
®
G36D Zero Clearance Direct Vent Gas Fireplace
®
Make a periodic check of burner for proper
position and condition. Visually check the
fl ame of the burner periodically, making sure
the fl ames are steady; not lifting or fl oating.
If there is a problem, call a qualifi ed service
The appliance and venting system must be
inspected before use, and at least annually,
by a qualifi ed fi eld service person, to ensure
that the fl ow of combustion and ventilation
Note: Never operate the appliance without
the glass properly secured in
Do not use this appliance if any part has been
under water. Immediately call a qualifi ed
service technician to inspect the appliance
and to replace any part of the control system
and any gas control which has been under
Verify operation after servicing.
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or
streaks, and in extreme cases, holes.
These components should be replaced
Remove the Cap, and shine a fl ashlight
down the Vent. Remove any bird nests, or
Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and fi ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
Inspect joints, to verify that no pipe
sections or fi ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
The 24 carat gold plated or brass fi nish on the
trim requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as they
may harm the fi nish and void the warranty.
Clean any fi ngerprints off before turning the
unit on. If the top louvers start to discolour,
check the door gasket seal and replace if
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Note: Improper positioning of logs may create
carbon build-up and will severely alter
the unit's performance which is not
Loosen the thermocouple or thermopile with
Disconnect thermocouple by loosening
nut from the valve with a 9mm wrench.
Disconnect thermopile by loosening 2 screws
Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
Reinstall the new ones in reverse order.
If the glass gasket requires replacement use
a tadpole glass gasket for the Flush Front (Part
fi replace is supplied with high
temperature, 5 mm tempered glass that will
withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
In the event that you break your glass by impact,
purchase your replacement from an authorized
dealer only, and follow our step-by-
®
dealer only, and follow our step-by-
®
step instructions for replacement.
: Do not operate the appliance
with the glass panels removed, cracked
or broken. Replacement of the glass
panels should be done by a licensed
or qualifi ed service person.
Caution: Wear gloves when removing
Remove the fl ush door front (as per instructions
in the "Standard Flush Door" section). Remove
the 4 glass clips from each corner. Slide in the
new replacement glass. Push the 4 glass clips