![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/f5/6f5c8cc0-90b8-41a8-8c0c-b764c287eda8/6f5c8cc0-90b8-41a8-8c0c-b764c287eda8-bg2f.png)
Rockwell Automation Publication 1412-UM001D-EN-P - September 2012 47
Display Modes Chapter 3
It is possible to make an energy measurement over several recording ranges in the
4 quadrants.
The Plus and Minus buttons allow the integration period of the
displayed measurement and the graph time-scale to be changed.
Save the Display
This button lets you save 12 snapshots for future recall and evaluation:
• Press the Camera button (for about 3s) to capture a snapshot of the
current display.
• The Camera icon is displayed in the top left corner as soon as the
operation is successful.
• This icon is replaced by the Trash Can if there is no space left in the
memory to record the display.
All data in a recording session can be downloaded to a computer by using the
DATAVIEW software.
Display Averaging Period Graph Scale
2 hours over 5 days
1 hour over 2 1/2 days
15 minutes over 15 hours
10 minutes over 10 hours
5 minutes over 5 hours
1 minute over 1 hour
20 seconds over 20 minutes
5 seconds over 5 minutes
1 second over 1 minute
The minimum integration period is limited by the recording period. The
recording integration period of two minutes is a special case. In this case, only
the following display integration periods are possible: 10 minutes, one hour,
and two hours.
These screens can be downloaded to a computer via the DATAVIEW software.