OPTION SETTING
☞
Option settings
•
CONTROL setting:
This sets whether other peripheral devices
can be used to operate the camera by means of the RS-485
interface or a linked coaxial cable.
•
ADDRESS setting:
Use this to set the address for this camera
when more than one camera is connected or when other
peripheral devices or a system controller have been connected.
(See p57)
•
ALARM setting:
This is used for settings related to alarm
input and alarm output. In addition, it is also used to force
selection of COLOR mode or B/W mode when the
DAY/NIGHT setting function is being used. (See p57)
CONTROL setting
1
Use the cursor button (
j
or
l
) to move the cursor to
SET for OPTION, then press the SET button.
The OPTION screen will appear.
Note:
The PRESET ON setting cannot be used when OPTION
settings are in use.
2
Use the cursor button (
j
or
l
) to move the cursor to
485 for CONTROL, use the cursor button (
d
or
c
) to
select the device to be operated (e.g. 485), and then
press the SET button.
The RS-485 SETTING screen will appear.
Available settings:
•
485:
For operation by the System Controller
•
COAX:
For operation of device by linked coax cable.
3
Use the cursor button (
d
or
c
) to select 19200 for BAUD
RATE.
Available settings:
19200, 9600, 4800, 2400
4
Use the cursor button (
j
or
l
) to move the cursor to
TERMINATE, and then use the cursor button (
d
or
c
) to
select the terminate setting.
☞
To close the menu screen or return to the previous
screen, select BACK or END for MENU and press the SET
button.
12 3 4
MAIN MENU
LANGUAGE SET ‚
CAMERA ID OFF
SYNC INT
PRIVACY MASK SET ‚
LENS SET ‚
MIRROR OFF
VIEW SETTING 1 ‚
OPTION SET ‚
OPTION
CONTROL 485 ‚
ADDRESS 0
ALARM SET ‚
RS-485 SETTING
BAUD RATE 19200
TERMINATE OFF
RS-485 SETTING
BAUD RATE 19200
TERMINATE OFF
L5AD2/US (VCC-ZM400) GB 2003, 2, 4
English