153
Software Fixes in Release K.11.12 - K.13.49
Release K.11.40
Software Exception at rt_table.c.758 -- in 'eRouteCtrl', task ID =
0x8a d6b30 -> Routing Task: Route Destinations exceeded
Release K.11.40
The following problems were resolved in release K.11.40 (not a general release)
■ CLI (PR_1000353548) — Use of the command show span incorrectly displays an error,
"STP version was changed. To activate the change you must save the
configuration to flash and reboot the device."
■ Crash (PR_1000352922) — The switch may crash with a message similar to
mstp_ptx_sm.c:118 -- in 'mMstpCtrl', task ID = 0x8899e70 -> ASSERT:
failed
■ Enhancement (PR_1000346164) — RSTP/MSTP BPDU Protection: When this feature is
enabled on a port, the switch will disable (drop the link) a port that receives a spanning tree
BPDU, log a message, and optionally, send an SNMP TRAP.
Release K.11.41
The following problems were resolved in release K.11.41
■ Enhancement (PR_1000344652) — Added support for Unidirectional Fiber Break
Detection.
■ Hang (PR_1000346328) — Switch hangs during initialization, switch may fail to boot.
RMON alarms/events configuration files corrupted.
■ MDI/MDI-X (PR_1000354050) — Forced MDI and MDIX modes were reversed on the
3500yl - forced MDI was transmitting out pins 3 and 6 instead of 1 and 2, and vice versa.
■ Port Monitoring (PR_1000354067) — The CLI does not allow users to mirror mesh ports,
resulting in "Error setting value monitor for port <n>".
■ SSH (PR_1000350999) — The SSH login prompts user to "press any key to continue" twice
before providing a prompt.
■ Web-UI (PR_1000354104) — The Web-UI limited the size of the "Common Name" field in
the SSL configuration tab to 16 characters
Release K.11.43
Version K.11.42 was never released.