Sense Data Values
136 ESL E-Series Tape Library User’s Guide
580 22ELEMENT CONTENTS UNKNOWN
The contents of an element address are unknown. Issue a Read
Element Status for the element address. If contents are still unknown
issue an Initialize Element Status command.
480 23BAR CODE SCANNER FAILURE
Bar code scanner has failed. Reinitialize element status.
4 81 See
Table 23
PICKER HARDWARE FAILURE
Picker hardware failure. Call Technical Support.
581C0TRANSPORT FULL
The picker contains a cartridge. Issue a command to retrieve the
cartridge from the picker and place it in either a bin or a tape drive.
581 E0PICKER INVALID START CONDITION
Picker hardware condition is unknown. Issue a Rezero Unit
command.
581 F0PICKER INVALID COMMAND
Picker hardware commanded to position out of system mechanical
limits. Issue a Rezero Unit command.
4 82 See
Table 23
ROTARY HARDWARE FAILURE
Rotary hardware failure. Call Technical Support.
582 E0ROTARY INVALID START CONDITION
Rotary hardware condition is unknown. Issue a Rezero Unit
command.
582 F0ROTARY INVALID COMMAND
Rotary axis was commanded to a position out of its legal range. This
is an internal code failure.
4 83 See
Table 23
EXTENSION HARDWARE FAILURE
Extension hardware failure. Call Technical Support.
Table 22: Sense data values (Hexadecimal) (Continued)
Sense
Key
ASC ASCQ Message Name/Description