A SERVICE OF

logo

5
Notice
The following safety features are included in each melt unit:
The tank, hose, and applicator head are monitored for over temperature conditions. The affected zone is shut down if
an error condition is detected. The circuit breaker is automatically tripped when the tank is sensed to be over
temperature.
A passive over temperature sensor trips the melt unit circuit breaker before irreparable damage occurs to the unit in
the unlikely event that the closed loop electronics should malfunction, resulting in a runaway heating condition in
the melt unit.
Operation of the pump/motor is inhibited until the melt tank reaches 80% of the selected temperature. This prevents
damage to the pump/motor by attempting to operate while the adhesive is too viscous to be pumped.
a. Items Supplied
Carefully remove the unit from its shipping carton and inspect it for any signs of damage. Any damage should be
reported immediately to the carrier. Refer to the list of supplied parts below and compare to the contents. Report
any missing parts promptly to the Henkel customer service department at 1-800-LOCTITE or 1-800-562-8483.
Operators Manual, P/N 987520
10 mm Hex Key, P/N 987842
Trim Potentiometer Tool for temperature range adjustment, P/N 987841