Polycom RealPresence Collaboration Server (RMX) 1500/2000/4000 Administrator’s Guide
21-40 Polycom, Inc.
Enabling Hot Backup
To enable Hot Backup:
1 On the RMX menu, click Setup > Hot Backup.
The RMX Hot Backup dialog box is displayed.
2 Complete or modify the following fields:
3 Click OK.
Using Hot Backup Triggers
Hot Backup is initiated by the slave MCU on detection of no response from the master MCU
on a “Keep Alive” operation. The Hot Backup triggers initiates the Hot Backup swap from
Master to Slave when the selected conditions on the Master MCU occur.
Table 21-4 Hot Backup
Field Description
Hot Backup Enabled Select this check box to enable Hot Backup.
MCU Role: This setting determines the role of the MCU in the Hot Backup
configuration.
Select either Master MCU or Slave MCU from the drop-down menu.
Paired MCU IP
Address
Enter the Control Unit IP Address of the:
Slave MCU (if this MCU is the Master)
Master MCU (if this MCU is the Slave)
Synchronization
Status
The status of the synchronization between the Master and Slave
MCUs in the Hot Backup configuration is indicated as:
OK - Hot Backup is functioning normally, and the Master and
Slave MCUs are synchronized.
Attempting - Hot Backup is attempting to synchronize the Master
and Slave MCUs.
Fail - A failure occurred while trying to synchronize the paired
MCUs.
None - Hot Backup has not been enabled.