4.2.3 Setting Commands
Card Settings
= CV (Card Volume label)
Function: Card name setting
Syntax: stxCV: * ,“********”, ***** ;
a b c
a Card in slot
0 Card in slot A
1 Card in slot B
b Card name (up to 8 characters)
c Reserved (Only '0')
Example) stxCV:0,“ABCDEFGH”, 0;
This specifies a name of “ABCDEFGH” for the card in slot A.
Pattern Phrase Settings
< PU (Pattern phrase set Up for AR-2000)
Function: Pattern Phrase settings
Syntax: stxPU: **** , * , **** , **S* , .... , **** , **S* ;
a b c d .... c d
a Pattern Phrase number
b Pattern Phrase Playback mode
0 Sequence
1 Random
c Phrase number to be played back
d Delay Time (0S0 - 59S9)
Example) PU:A1,0,A5,5S0,A10,15S1,B151,10S0;
For phrase number “A0001”, this registers a “Sequential playback” pattern phrase
consisting of the following; phrase number “A0005”, a delay of “5 seconds”, phrase
number “A0010”, a delay of “15.1 seconds”, phrase number “B0151”, and a delay of
“10 seconds”.
Note: A maximum of 100 phrases can be specified in one line.
For the pattern phrase number, specify a phrase number where nothing is recorded.
For the playback phrase number, Audio phrases, MIDI phrases, and pattern phrases
can be specified.