Specifying Alarm Output
For accessing the MAIN MENU, see page 13 14.
If you have connected an external beeper or indicator to the alarm output terminal (ALARM OUT) on the rear
panel, specify the following settings. You can also obtain a notification on the screen while an alarm occurs.
(For connecting alarm devices, see page 10.)
1
11
1
Select POLARITY and specify a polarity for the
signal.
NO: Normal Open (Closes when alarm input is detected).
NC : Normal Close (Opens when alarm input is detected).
2
22
2
Select ALARM TIME and specify duration time
to output alarm.
Select from: 5S, 10S, 15S, 20S, 30S, 1M, 2M, 3M, 4M or 5M
(S = second, M = minute)
3
33
3
Set MENU to END and press the SET button.
RFinishes the settings screen and returns to the normal
monitoring screen.
If you want to return to the previous screen, select BACK and
press the SET button.
ALARM OUT SETTING (Alarm output)
ALARM
OUT
ON
SET
ALARM
(SET)
SET
MAIN MENU
LANGUAGE SET
TITLE OFF
SYNC INT
EXPOSURE SET
DAY/NIGHT AUTO
WHITE BALANCE ATW
OPTION SET
PRESET OFF
MENU END
ALARM SET
ALARM SETTING
ALARM SIGN OFF
PRESET OFF
MENU BACK
ALARM IN SET
ALARM OUT ON
MEMO:
For the electrical characteristics of alarm output, the
nominal output of the open collector (grounded emitter) is
18 V 25 mA.
ALARM OUT SETTING
ALARM TIME 5S
POLARITY
NO
MEMO: You can display alarm on the monitor screen.
(See page 45)