4 Sun Blade X6270 Server Module Installation Guide December 2009
Environmental Requirements
TABLE 1-3 gives the environmental requirements for the Sun Blade X6270 Server
Module.
Server Module Installation Task
Checklist
TABLE 1-4 summarizes an ordered list of tasks that you must perform to properly
install the server module into a Sun Blade 6000 or 6048 Series Modular System.
TABLE 1-3 Sun Blade X6270 Server Module Environmental Requirements
Condition Requirement
Operating temperature 5
o
Cto35
o
C noncondensing
Nonoperating
temperature
-40
o
Cto65
o
C
Operating humidity 10% to 90% noncondensing (27
o
C max. wet bulb)
Nonoperating humidity 93% noncondensing (38
o
C max. wet bulb)
Operating altitude 3048 meters at 35
o
C
Nonoperating altitude 12,000 meters
TABLE 1-4 Installation Task Checklist
Step Task Description For Instructions, See:
1 Unpack the Sun Blade X6270 Server
Module and any optional components
ordered for the server from the
shipping containers.
Chapter 1 “About Your Server
Module Shipment” on page 1
2 If applicable, install the optional server
module components prior to installing
the server module into the chassis.
Chapter 2 “Install Server Module
Optional Components” on page 7
3 Install the server module into a
powered-on Sun Blade 6000 or 6048
Series Chassis.
Chapter 3 “Installing and Powering
On the Sun Blade X6270 Server
Module” on page 33
4 Verify the power state of the server
module and apply main power to the
server module SP and host.
Chapter 3 “Installing and Powering
On the Sun Blade X6270 Server
Module” on page 33