A SERVICE OF

logo

4
General Information
Model Number Description
All products are identified by a multiple character model
number listed on the unit nameplate. An explanation of the
alphanumeric identification code is provided below. Its use
can define the unit's specific components, type of applica-
tion, i.e. CV or VAV, for a particular unit.
When ordering replacement parts or requesting service, be
sure to refer to the specific model number, serial number,
and DL number (if applicable) stamped on the unit name-
plate.
Sam
p
le Model No.: S X H F - C20 4 0 A 1 0 A 1 5 B 1 D 0 1 A,R,L,etc.
Digit No.: 1 2 3 4 5,6,7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+
Digit 1 - Unit Type Digit 10 - Design Sequence Digit 17 - System Control
S = Self-Contained 3 = Disconnect Redesign 1 = CV Control (Zone Control)
Note: Sequence may be any letter
2 = VAV-(
S/
A Temp
C
ontrol
Di
g
it 2 - Unit Function A thru Z, or an
y
di
g
it 1 thru 9.
without Inlet Guide Vanes)
A = DX Cooling, No Heat 3 = VAV-(S/A Temp Control
E = DX
C
ooling, Electric Heat
Digit 11 - Exhaust Option
with Inlet
G
uide Vanes)
F = DX Cooling, Natural Gas Heat 0 = None 4 = Space Pressure Control with Exhaust VFD
L = DX Cooling, Hot Water Heat 1 = Barometric without Bypass
S = DX Cooling, Steam Heat 2 = 100% - 1.5 HP* 5 = Space Pressure Control with Exhaust VFD
X = DX Cooling, Extended Casings 3 = 100% - 3 HP* and Bypass
# = DX Cooling, Propane Gas Heat 4 = 100% - 5 HP* 6 = VAV Supply Air Temperature Control
5 = 100% - 7.5 HP* with VFD w/o Bypass
Di
g
it 3 - Unit Airflow
6 = 100% - 10 HP* 7 = VAV Supply Air Temperature Control
H = Single-Zone 7 = 100% - 15 HP* with VFD and Bypass
8 = 100% - 20 HP* 8 = Supply and Exhaust Fan with VFD
Di
g
it 4 - Develo
p
ment Se
q
uence
A = 50% - 1.5 HP without Bypass
F = Sixth B = 50% - 3 HP 9 = Supply and Exhaust Fan with VFD
C = 50% - 5 HP and Bypass
Di
g
its 5, 6, 7 - Nominal Ca
p
acit
y
D = 50% - 7.5 HP
C
20 = 20 Tons
C
55 = 55 Tons E = 100% - 1.5 HP**
Di
g
it 18 - Accessor
y
Panel
C25 = 25 Tons C60 = 60 Tons F = 100% - 3 HP** 0 = None
C30 = 30 Tons C70 = 70 Tons G = 100% - 5 HP** A = BAYSENS008*
C40 = 40 Tons C75 = 75 Tons H = 100% - 7.5 HP** B = BAYSENS010*
C50 = 50 Tons J = 100% - 10 HP** C = BAYSENS013*
K = 100% - 15 HP** D = BAYSENS014*
Digit 8 - Power Supply
L = 100% - 20 HP** E = BAY
S
EN
S
019*
4 = 460/60/3 XL # = 50% w/ Statitrac F = BAYSENS020*
5 = 575/60/3 XL * w/Statitrac G = BAYSENS021*
E = 200/60/3 XL ** w/o Statitrac (CV only)
F = 230/60/3 XL
Di
g
it 19 - Ambient Control
Note: SEHF units
(
unit with Di
g
it 12 - Exhaust Fan Drive
0 =
S
tandard
electric heat) utilizing 208V or
0 = None 8 = 800 PRM 1 = 0 Degree Fahrenheit
230V re
q
uire dual
p
ower source.
4 = 400 RPM 9 = 900 RPM
5 = 500 RPM A = 1000 RPM
Di
g
it 20 - A
g
enc
y
A
pp
roval
Digit 9 - Heating Capacity
6 = 600 RPM B = 1100 RPM 0 = None (UL Gas Heater, see note)
7 = 700 RPM 1 = UL
Note: When the second di
g
it
2 =
CS
A
calls for "F" (Gas Heat), the Digit 13 - Filter Type Note: Includes UL clsssified gas heating
followin
g
values a
pp
l
y
:
A = Throwaway
section onl
y
when second di
g
it of
Additionall
y
,
p
lease note G and
B =
C
leanable Wire Mesh
Model No. is a "F".
M available ONLY on 50 Ton
C = High-Efficiency Throwaway
models and above.
D = Bag with Prefilters
Di
g
its 21 - 38 - Miscellaneous
H = High Heat - 2 Stage E = Cartridge with Prefilters 21 A = Unit Disconnect Switch
L = Low Heat - 2 Stage F = No Filters (T/A Rack Only) 22 B = Hot Gas Bypass
0 = No Heat G = No Filters (Bag/Cart. Rack Only) 23 C = Economizer Control w/Comparative
J = Limited Modulating High Heat Enthalpy
G = Limited Modulating Low Heat
Digit 14 - Supply Fan Horsepower
23 Z = Economizer Control w/Reference
P = Full Modulating High Heat 1 = 3.0 HP 6 = 20.0 HP Enthalpy
M = Full Modulating Low Heat 2 = 5.0 HP 7 = 25.0 HP 23 W = Economizer
C
ontrol w
/
Dry Bulb
Note: When the second digit
3 = 7.5 HP 8 = 30.0 HP 23 O = None W/O Economizer
calls for "E" (electric heat), the
4 = 10.0 HP 9 = 40.0 HP
1
24 E = Low Leak Fresh Air Dampers
followin
g
values a
pp
l
y
:
5 = 15.0 HP 25 F = High Duct Temperature Thermostat
D = 30 KW R = 130 KW 26 G = High Capacity Evaporator Coil
H = 50 KW U = 150 KW
Di
g
it 15 - Su
pp
l
y
Fan Drive
27 H = Copper Fins (Cond. only)
L = 70 KW V = 170 KW 5 = 500 RPM B = 1100 RPM 28 K = Generic B.A.S. Module
N = 90 KW W = 190 KW 6 = 600 RPM C = 1200 RPM 29 L = High-Efficiency Motors (Supply & Exhaust)
Q = 110 KW 7 = 700 RPM D = 1300 RPM 30 M = Remote Human Interface
Note: When the second di
g
it calls
8 = 800 RPM E = 1400 RPM 31 N = Ventilation
O
verride Module
"L" (Hot Water) or "S" (Steam)
9 = 900 RPM F = 1500 RPM 32 R = Extended Grease Lines
Heat, one of the followin
g
valve
A = 1000 RPM
G
= 1600 RPM 33 T = Access Doors
size values must be in Digit 9:
34 V = Interprocessor
C
ommunications Bridge
High Heat Coil: 1 = 50", 2 = .75",
Di
g
it 16 - Fresh Air Section
35 0 = No communication module
3 = 1", 4 = 1.25", 5 = 1.5", 6 = 2". A = No Fresh Air 35 Y = Trane Communication Interface Module
Low Heat Coil: A = .50", B = .75", B = 0-25% Manual 35 7 = LonTalkĀ® Communication Interface Module
C = 1", D = 1.25", E = 1.5", F = 2". D = 0-100% Economizer 36 8 = Spring Isolators
37 6 = Factory-Powered 15A GFI Convenience
Outlet
38 0 = None
1. Available as standard 460 volt only for 70 and 75 ton models.