Acer F900 Cell Phone User Manual


 
Chapter 4 7
G Sensor and Light Sensor Tests
NOTE:
Wear anti-static gloves.
Take care not to damage the casing when putting the device on the test fixture.
Ensure the Light Sensor Test Fixture timer is reset to 0 (zero) before use.
Please use the Golden Sample to calibrate tests before use.
1. Press OK to start the G Sensor Test.
2. Tap Start to begin the test.
3. The screen shows Z, -Z, X, -X, Y, and -Y on the screen. After
each position, move the handset according to the specified
directions as follows:
Z: Handset screen faces up
-Z: Turn handset so that battery cover faces up
X: Rotate handset clockwise 90 degrees.
-X: Rotate handset anti-clockwise 90 degrees.
Y: Rotate handset clockwise 180 degrees.
-Y: Keep handset in normal position, facing up.
4. After each position shift, the handset beeps to indicate that
you should change the position. A set of 6 beeps indicates
that the device passed the test.
5. Tap Light Sensor Test to enter the Light Sensor test page.
6. Tap Start to begin the test.
7. If the screen shows PASS, the device has passed the test.