Hill Phoenix OSAA Carrying Case User Manual


 
12
PLUMBING
The drain outlet is located front and
center of the cases for convenient access
and is specially molded out of ABS material.
The “P” trap, furnished with the case, is
constructed of schedule 40 PVC pipe. Care
should be given to assure that all connec-
tions are water tight and sealed with the
appropriate PVC or ABS cement.
The drain lines can be run left or right
of the tee with the proper pitch to satisfy
local drainage requirements. The drain can
be piped to a evaporative drain pan at the
owners option.
The kickplate is shipped loose with the
case for field installation, therefore you
should have open access to the drain line
area.
If the kickplate has been installed, you
will find it very easy to remove. See instruc-
tions below, or the trim out section of this
manual on page 9.
LIFT UP FROM “J”
RAIL AND PULL OUT
KICKPLATE
“J” RAIL
HOW TO REMOVE KICKPLATE
5 13/16 in [14.7 cm]
38 5/16 in
[97.3 cm]
49 1/16 in
[124.6 cm]
34 1/2 in
[87.6 cm]
1 1/2" PVC DRAIN
CONNECTION
FRONT OF CASE
1 1/2 in [3.8 cm]
{END}
21 1/2 in
[54.6 cm]
**
34 9/16 in
[87.7 cm]
NOTES:
** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS
C
L
72 in [182.9 cm] {6' case}
DRAIN PAN
(optional)
MODEL OSAA