Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
TABLE 1 – Minimum Separations Guide
Interferer Clearance
Fluorescent lighting 12 ” (305 mm)
Power cables (110V) 12 ” (305 mm)
Unshielded power <2kVA 5 ” (127 mm)
Unshielded Power >5kVA 24 ” (610 mm)
Transformers / motors / elevators 40 ” (1016 mm)
Diagram 4: Correct placement of cables and outlets
4.5 Telephones And Communications Devices In Bathrooms
The Canada Electrical Code, Rule 60-400 in summary provides: Communication
equipment located in a bathroom shall be permanently fixed on the wall, and shall be
located so that no part may be reached or used from the bath or from the shower
enclosure.
Telephone jacks are not permitted in bathrooms.