Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
11.1 ORTRONICS MDUTSP - IDC / Pin Identification
INCOMING JACK
o IDC on the back to a RJ45 on the front
4 pair feed from NIB is terminated on the IDC
Pr 1 – Dialtone
Pr 2 – Vacant
Pr 3 – DSL Signal
Pr 4 – Reserved for 2
nd
line
All Pairs are connected through to the RJ45 Incoming Jack
Pair 1 connects to Pins 4 & 5
Pair 2 connects to Pins 3 & 6
Pair 3 connects to Pins 1 & 2
Pair 4 connects to Pins 7 & 8
RJ45 patch cord (included) then patch dial tone to “security in”.
Blank is included for future use if required. An addition RJ45 may be
inserted.
SECURITY JACK
o IN JACK
All 4 pairs plugged into “security in”, Pair 1 is bridged to “in” of RJ31X for
POTS service only when a RJ45 plug is inserted into “RJ31X” port
Pairs1 2, 3 & 4 from the RJ45 are distributed to “security out”
o RJ31X JACK
When the cord to the Alarm Panel is plugged in, dialtone is routed thru the
alarm panel and back out to the out of the RJ31X
Out pair of RJ31X bridged to pair 1 of OUT
o OUT JACK
Patch Cord from OUT to ADO to feed dialtone and DSL to jacks
ADO JACK
o Pairs 1 & 4 are bridged to pairs 1 & 4 of LOC 1 thru LOC 13 and EXP
When the patch cord from SECURITY OUT is connected, dialtone is
supplied to LOC 1 thru LOC 13 and EXP jacks
When the patch cord from SECURITY OUT is connected, DSL is supplied
to “DATA INTO MODEM”
Pairs 2 & 3 are bridged to “DATA INTO MODEM”
DATA INTO MODEM JACK
o RJ11 cord feeds DSL signal to modem (PAIRS 2 & 3, PINS 1,2 & 3,6)
LOC 1 thru LOC13 & EXP JACKS
o Pairs 1 & 4 are bridged between jacks
o Straight 4-pair IDC on the back to a RJ45 on the front
Inside wire set runs providing POTS and DSL services are terminated on
LOC1 thru LOC13 as required
DSL service is provided to the individual room outlets when a patch cord is
connected from the modem or router as required
Pairs 2 & 3 are passed to IDC on rear at each location(non-bridged)
TV JACKS
o Straight 4-pair IDC on the back to a RJ45 on the front (CAT 5e)
Designated TELUS TV inside wire set runs are terminated as required
Service is provided when a patch cord is connected from a switch
AUX JACKS
o Straight 4-pair IDC on the back to a RJ45 on the front (CAT 5e)
For future expansion
TELUS Communications Inc. (c) 2006-9-22 Page 29