Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
The TELUS Panel: Ortronics MDUTSP
This distribution panel mounts inside the Ortronics Connect series enclosures and TELUS
enclosures. These panels distribute TELUS TV, Telephone, Data (Ethernet) and have a
Security port to interface with alarm panels.
See Section 11: Appendix C: DD Panel Configuration (Ortronics)
6.2 Installation Best Practices
1. Required Space – Ortronics Enclosure
2. Distribution Panel – TELUS MDUTSP1
3. Entry point for runs from Multimedia Outlets in rooms and cable run from NIB.
4. Multiple cat 5e runs from rooms and NIB
5. Entry points to DD Distribution Enclosure
6. Reserved area to mount Modem and Router
7.
Un-switched 120V Duplex outlet
8. For larger homes with more runs, additional components may be required.
Locate your DD panel or cabinet no closer than 12" (30cm) to a power distribution panel,
suggested distance is 24" or 60cm, to protect network equipment from sources of
interference.
Clearly mark all set runs, with MO location id and type of service on each (if known)
suggested e.g. MBR01, KTCH01, DNGR01, LIVR01a LIVR01b. Clearly identify and mark
all services and ports.
Use a tone generator or Fluke MicroscannerPro kit to assist in determining which cable
runs connects to which room. See instructions supplied with your tool.
6.3 Connecting ADSL Service
For single room outlet requiring ADSL service:
1. patch RJ-11 jumper from RJ-11 jack marked ADSL to the RJ-11 jack on
modem
2. patch RJ-45 jumper from ADSL modem to appropriate room outlet jack
For multiple outlets requiring service:
1. install a switch or residential gateway
2. patch RJ-11 jumper from RJ-11 jack marked ADSL to the RJ-11 jack on
modem
3. patch RJ-45 jumper from ADSL Modem Ethernet port into one
switch/gateway/router port (possibly marked WAN or UPLINK port); patch all
TELUS Communications Inc. (c) 2006-9-22 Page 21