![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/f7/af7d1b5d-9052-4162-bd37-fcbe5143425c/af7d1b5d-9052-4162-bd37-fcbe5143425c-bg6.png)
Units after Serial Number Break (VC4GD 481835388,
VC6GD 481835406, VC4GD 541077665) Natural
Gas - 50,000 BTU input at 5.0 in. W.C.
Propane Gas - 44,000 BTU input at 10.0 in. W.C.
Units after Serial Number Break (VC4GD 481835394
& 541077965, VC6GD 481835429) Propane Gas -
50,000 BTU input at 10.0 in. W.C.
Gas Line Pressures
Natural - Recommend (in. W.C.) 7.0, Min 5.0
Natural - Recommend (in W.C.) 8.0, Min 6.0 for Units
after Serial Number Break (VC4GD 481835388,
VC6GD 481835406, VC4GD 541077665)
Propane - Recommend (in. W.C.) 11.0, Min 11.0 (All
Propane Units)
Maximum 14.0 in. W.C. (Nat. or Prop.)
TOOLS
Standard
• Standard set of hand tools
• VOM with ability to measure micro amp current
VOM with minimum of NFPA-70E CAT III 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt. Meter leads must also be rated at
CAT III 600V.
• Gear Puller to remove blower
Special
• Temperature tester (thermocouple type)
• Manometer
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - GENERAL