47
4. Safety regulations
Persons using the explosion-protected Ex-GSM 01 mobile telephone
must observe the standard safety regulations and read the certificate to
prevent incorrect operation or misuse of the unit.
The following safety regulations must be observed in addition:
- The unit must not be opened within the Ex-area.
- After using the unit in Zone 22, the combination charging and accessory
connection socket must be inspected for contamination and if required,
cleaned with a brush or by blowing off with compressed air.
- In Zone 22, the unit may only be used within an atmosphere containing
non-conductive dusts.
- Use only the original battery module Ex-AM GSM 01
(Li-Ion 3.7 V/820 mAh)!
- The battery module must not be changed within the Ex-area!
- The battery module may only be charged outside the Ex-area using the
related original charger type LGH G01 resp. the charging ability of the
Carkit CK G01!
- It must be ensured that the unit is not taken into zones 0 or 1, or zones
20 and 21!
- Only the accessories listed in the accessories list (0163EX07A) may be
used within the Ex-area.
- The mobile telephone is not watertight; please be sure to keep it dry!
- If you use the mobile telephone while driving a motor vehicle, be sure to
observe the respective national laws!
- The mobile telephone may not be used on an airplane!
- Turn the mobile telephone off when in the vicinity of medical devices if
so requested by the respective regulations!
- Manufacturers of cardiac pacemakers recommend keeping a minimum
interval of 15.3 cm (6“) between a mobile telephone and a pacemaker.
- Do not turn the mobile telephone on if the use of mobile telephones is
prohibited; it could result in intererence or pose hazards.
5. Ex-data
Type examination certificate no.: TÜV 06 ATEX 7371 X
Ex designation: II 3 G EEx nA nL IIC T6
II 3 D Ex tD A22 IP54 T75°C
Notice nL, nA:
n = not an ignition source in normal operation
L – limited energy operating device
A = non-sparking