GE NX-7002 Cell Phone User Manual


 
LOCATION 1 DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment)
The NX-7002 contains up to six report controls. Each report control can be defined for SMS
reporting, TCP/IP reporting or email reporting (not yet available). This location contains the
report destination for report control 1. Select from the table below.
DATA FORMAT DESCRIPTION
0 Disabled Report control 1 is disabled
1 TCP/IP 1 Reporting to TCP/IP receiver 1
2 TCP/IP 2 Reporting to TCP/IP receiver 2
3 Email 1 Email Reporting to Email Account 1 (not yet
available)
4 Email 2 Email Reporting to Email Account 2 (not yet
available)
5 SMS 1 SMS Reporting to Mobile Phone 1
6 SMS 2 SMS Reporting to Mobile Phone 2
LOCATION 2 BACKUP DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment)
If the primary destination selection (location 1) fails, a backup destination can be selected. If
using another device as the backup destination, for example, panel dialler, set the reporting
format (SIA or CID) in location 0, segment 2, option 1 and enable test report events for the
backup device. This location contains the backup report destination for report control 1. Select
from the table below.
DATA FORMAT DESCRIPTION
0 Disabled Backup Report control 1 is disabled
1 TCP/IP 1 Backup Reporting to TCP/IP receiver 1
2 TCP/IP 2 Backup Reporting to TCP/IP receiver 2
3 Email 1 Backup Email Reporting to Email Account 1 (not yet
available)
4 Email 2 Backup Email Reporting to Email Account 2 (not yet
available)
5 SMS 1 Backup SMS Reporting to Mobile Phone 1
6 SMS 2 Backup SMS Reporting to Mobile Phone 2
255 Other dialler The NX-7002 is not used as backup. Instead another
dialler is used (for example: panel dialler)
LOCATION 3 REPORT DELAY FOR REPORT CONTROL 1 (1 segment)
The delay in seconds before the NX-7002 GPRS module reports. If any other events occur
during this delay, they are sent with the first event in one message if using SMS reporting. This
does not apply if using TCP/IP reporting (it does not support multiple events in one message).
This can be from 0 to 255 seconds.
NX-7002 Installation manual Page 14 09/02/05