Polycom 8030 Cell Phone User Manual


 
SpectraLink 8020/8030 Wireless Telephone: Administration Guide for SRP
40 1725-36030-001_B.doc
Configuration Process
1. Download the latest SpectraLink 8020/8030 Wireless Telephone
software from http://www.spectralink.com/softwareUpdates
2. Place the latest version of the SpectraLink 8020 or 8030 Wireless
Telephone SRP code on the TFTP server and ensure the TFTP
server is started. The five files that are needed must be named:
usb downloader pd14udsp.bin
functional filename pd14csp.bin
phintl filename pi1400sp.bin
ota downloader pd14odsp.bin
config file slnk_cfg.cfg
3. See SpectraLink 8000 Telephony Gateway: Administration Guide to set
the TFTP server information.
4. Use the Handset Administration Tool to set up the configuration
of each handset to meet all essential requirements. If not using the
Handset Administration Tool, ensure the following parameters
are correctly set in the Admin menu for each handset: See Chapter
2 SpectraLink 8020/8030 Wireless Telephone Configuration for
detailed configuration instructions.
If statically assigning IP addresses, ensure that the Phone IP,
Subnet Mask, and Default Gateway information are accurate. If
using a DHCP Server, ensure that the DHCP option is set.
Ensure the handset has properly configured SSID and Reg
Domain information.
Ensure the Telephony Protocol menu option is set to 030. This
ensures the handset will check for the proper SRP files each
time it powers on.
Ensure security settings are properly programmed.
5. Power cycle the handset.
6. The SRP code will now download to the handset. The status bar
will increment fully across the display for each function that is
being performed in the download process and the filename will
display. Upon completion of the update process, the handset will
re-boot with the new firmware.