28 Configuring PAD/ATPAD Ports
PAD Profile Table Record
Configuration
Guidelines
When you configure the PAD Profile Table Record, use these guidelines:
• No blank Profile Names can exist.
• No duplicate Profile Names can exist.
• If parameter #113 is 1, then #1 must be 0.
• If parameter #114 is 0, then #115-#117 should also be 0.
• If parameter #115 is greater than 0, then #112 should be 0.
• Default profiles always exist in the device.
Refer to the tables of parameter values in the “Copying PAD Profile Tables into a
Configuration” section later in this chapter.
Accessing the PAD
Profile Table
Record
Follow these steps to access the PAD Profile Table record:
Step Action Result
1
Select
Configure
, from the CTP
Main menu.
The Configure menu appears.
2
Select
PAD Profile Table
from
the Configure menu.
The PAD Profile Table and its
parameters appear.
A prompt appears asking you to
configure the next parameter.
3
Enter the parameter values.
4
Press
<ESC
>
to return to the
Configure menu after you have
configured all parameters.