Dukane Manual Part No. 403–566–01
Section 7 – Process Control Menu
Parameter Description Figure No.Weld Method Minimum Value
Weld Time Ultrasound Gate Time 0.000 Second7–8, 7–16 30.000 Seconds
T
weld
Weld Energy Target Welding Energy 0 Joules7–10, 7–17Energy
Energy
Ground Detect
Ground Detect
Untimed Probe Only
Time
12000 Joules
†
E
weld
Max Weld Time Welding Time Limit 0.000 Second7–11, 7–18 30.000 Seconds
T
max
Max Weld Time Welding Time Limit 0.000 Second7–11, 7–18 30.000 Seconds
T
max
Scrub Time Scrub Gate Time 0.000 Second 0.150 Seconds
T
scrub
Probe Delay Post–Trigger Delay 0.000 Second7–14 30.000 Seconds
T
delay
Time & EnergyHold Time Post–Weld Hold Time 0.000 Second 30.000 Seconds
T
hold
Time & EnergyAfterburst Delay Burst Time Delay 0.000 Second7–27, 7–49
7–20
7–24, 7–46
7–28, 7–50
7–40
7–44
similiar to
7–42
similiar to
7–43
7–42
7–43
0.999 Second
T
delay
Time & Energy
Trigger Method
Press & Any* Timed Probe
Energy – Pressure 1Weld Energy Target Welding Energy 0 Joules 12000 Joules
†
E
1
weld
Press – Dual Pressure
Energy – Pressure 2Weld Energy Target Welding Energy 0 Joules 12000 Joules
†
E
2
weld
Press – Dual Pressure
Press & Any* Timed Probe
Energy – Pressure 1Max Weld Time Welding Time Limit 0.000 Second 30.000 Seconds
T
1
max
Press – Dual Pressure
Energy – Pressure 2Max Weld Time Welding Time Limit 0.000 Second 30.000 Seconds
T
2
max
Press – Dual Pressure
Press, MPC & Auto Probe
Press, MPC & Auto Probe
Untimed MPC/Auto Probe
Press & Any* Timed Probe
Weld Time Ultrasound Gate Time 0.000 Second 30.000 Seconds
T
2
weld
Time – Pressure 2Press – Dual Pressure
Weld Time Ultrasound Gate Time 0.000 Second 30.000 Seconds
T
1
weld
Time – Pressure 1Press – Dual Pressure
Press & Auto Probe
Press & Auto Probe
Press & Auto ProbeAfterburst Time Burst Gate Time 0.000 Second 0.999 Second
T
burst
Maximum ValueMenu Name
12000 Joules
†
= 20kHz, 30kHz and 40kHz DPC II Plus
1200.0 Joules
†
= 50kHz and 70kHz DPC II Plus
(Requires Power Output Module)
* Any Timed Probe = Timed Hand Probe
Timed MPC Probe
Timed Auto Probe
Table 7—II Parameter Min–Max Values
NOTE
The 50kHz/150 Watt DPC II Plus and the 70kHz/
100 Watt DPC II Plus have a maximum weld
energy setting (E
weld
) of 1200.0 Joules. The
reduced scaling permits the DPC to achieve
better adjustment resolution at low power
levels. All other models covered in this manual
have a maximum weld energy of 12,000 Joules.